Manual Smart Control Panel V2
The Smart Control Panel V2 (HSB-1) is a wireless, rechargeable keypad that lets you control your alarm system quickly and easily. You arm and disarm the alarm system with codes or RFID tags; the keypad comes with 2 RFID tags. Its features include multiple user codes, a doorbell button, a breathing backlight and a user-friendly design.
The product
Main features
- Modern design
- Wireless connection
- Breathing backlight
- Multiple user codes
- Built-in 3.7V / 1500mAh lithium battery
- Power input: USB-C 5V 1A
- Low battery warning
- Anti-tamper alarm
- Doorbell button
- Supports up to 10 RFID tags
- Microwave proximity sensor: automatic wake-up
- Light sensor: automatic brightness adjustment
Front
| Part | Description |
|---|---|
| Number keys | The digit keys 0 to 9 |
| Cancel / Return | The button with the cross, bottom left |
| Confirm | The button with the tick, to the right of the 0 |
| Away | The button showing a shield with an exit arrow |
| Home | The button showing a shield with a figure |
| Disarm | The button showing a shield with a dash |
| Doorbell button | The button with the bell |
| RFID touch area | The area marked "RFID" to the right of the buttons, where you hold up an RFID tag |
| Indicator | Lights next to the buttons on the right-hand side |
| Power indicator | The light at the top right |
| Microwave proximity sensor | The dark area at the bottom right |
Back
| Part | Description |
|---|---|
| Light sensor | Do not cover |
| Anti-dismantling switch | On the left side of the back plate |
| USB-C 5V 1A | Power connection |
| Battery switch | Turn on before use |
| Screw hole | Two screw holes at the bottom |
Power indicator
| Colour | Status | Meaning |
|---|---|---|
| Red | Solid | Charging |
| Red | Flashing | Low battery |
| Green | Solid | Activated / fully charged |
| Green | Flashing | Standby |
Installation
- Fix the hanging plate to the wall with screws.
- Place the keypad on the hanging plate.
- Tighten the anti-tamper screws at the bottom.
Pairing
Pairing with the alarm system
- Turn the device on with the battery switch.
- In the alarm system, find "Keypad" and start pairing mode.
- Press the doorbell button (the button with the bell) to send a signal to the alarm host.
Operation and settings
Default codes
- Default admin code: 9876
- User 1 code: 1234
- Users 2 and 3: not enabled
Arming and disarming the alarm
Enter the admin or user code, or use an RFID tag. Then press the button for the mode you want.
| Mode | Button |
|---|---|
| Away arm | Press "Away" (the shield with the exit arrow) |
| Home arm | Press "Home" (the shield with the figure) |
| Disarm | Press "Disarm" (the shield with the dash) |
Doorbell function
Press the doorbell button (the button with the bell). The alarm host then sounds the doorbell.
Signals
| Signal | Meaning |
|---|---|
| Two short beeps | Error |
| One long beep | Success |
Pairing RFID tags
- Enter the admin code and press confirm (the tick).
- Press 1 and then confirm.
- Hold the RFID tags against the sensor one at a time.
- Press confirm twice to stop. At this step, the manual shows the icon of the cross button.
Deleting all RFID tags
- Enter the admin code and press confirm.
- Press 2 and then confirm.
All RFID tags are deleted.
Setting the admin or user code
- Enter the admin code and press confirm.
- Choose which code you want to set and then press confirm:
- 3: set admin code
- 4: set user 1
- 5: set user 2
- 6: set user 3
- Enter a new code of 4 to 8 digits and press confirm.
- Enter the code again and press confirm.
Deleting a user
- Enter the admin code and press confirm.
- Choose which user you want to delete:
- 4: delete user 1
- 5: delete user 2
- 6: delete user 3
- Press confirm twice to delete.
Turning the microwave proximity sensor on or off
- Enter the admin code and press confirm.
- Press 7 and then confirm to turn the sensor on, or press 8 and then confirm to turn the sensor off.
The sensor wakes up the keypad automatically when someone comes within about 1 metre.
Good to know when setting up
- During setup, press cancel (the button with the cross) to go back to the previous menu.
- When entering a code, you can enter up to 12 digits. As long as the correct code appears somewhere in them, it is recognised.
Troubleshooting
Setup fails
If setup fails, the two codes you entered may not match. Try again.
Resetting the keypad
- Disconnect the power supply and turn off the battery switch.
- Press and hold cancel (the cross) and confirm (the tick).
- Turn on the battery switch.
- Keep holding the buttons for 10 seconds. A long beep means the reset is complete.
Good to know
- Do not cover the light sensor on the back.
- Turn on the battery switch before you use the keypad.
- The keypad supports up to 10 RFID tags.
Specifications
Keypad
| 433 MHz version | LoRa version | |
|---|---|---|
| Power supply | DC5V 1A | DC5V 1A |
| Battery | 3.7V 1500mAh lithium battery | 3.7V / 1500mAh lithium battery |
| Working current | <10mA | <10mA |
| Standby current | <100uA | <100uA |
| Wireless | 433MHz, eV1527 | LoRa |
| Receiving distance / range | 100 metres (open space) | 500 metres (open space) |
| Temperature | -10°C ~ 50°C | -10°C ~ 50°C |
| Humidity | <95% non-condensing | <95% non-condensing |
RFID tag
| RFID protocol | 125KHz, 4100/4200 |
| Maximum number of tags | 10 |
This text comes from the official Hozard manual. The drawings are in the original manual (PDF). Updated on 1 November 2026.