Manual Smart Control Panel V2

The Smart Control Panel V2 (HSB-1) is a wireless, rechargeable keypad that lets you control your alarm system quickly and easily. You arm and disarm the alarm system with codes or RFID tags; the keypad comes with 2 RFID tags. Its features include multiple user codes, a doorbell button, a breathing backlight and a user-friendly design.

The product

Main features

  • Modern design
  • Wireless connection
  • Breathing backlight
  • Multiple user codes
  • Built-in 3.7V / 1500mAh lithium battery
  • Power input: USB-C 5V 1A
  • Low battery warning
  • Anti-tamper alarm
  • Doorbell button
  • Supports up to 10 RFID tags
  • Microwave proximity sensor: automatic wake-up
  • Light sensor: automatic brightness adjustment

Front

PartDescription
Number keysThe digit keys 0 to 9
Cancel / ReturnThe button with the cross, bottom left
ConfirmThe button with the tick, to the right of the 0
AwayThe button showing a shield with an exit arrow
HomeThe button showing a shield with a figure
DisarmThe button showing a shield with a dash
Doorbell buttonThe button with the bell
RFID touch areaThe area marked "RFID" to the right of the buttons, where you hold up an RFID tag
IndicatorLights next to the buttons on the right-hand side
Power indicatorThe light at the top right
Microwave proximity sensorThe dark area at the bottom right

Back

PartDescription
Light sensorDo not cover
Anti-dismantling switchOn the left side of the back plate
USB-C 5V 1APower connection
Battery switchTurn on before use
Screw holeTwo screw holes at the bottom

Power indicator

ColourStatusMeaning
RedSolidCharging
RedFlashingLow battery
GreenSolidActivated / fully charged
GreenFlashingStandby

Installation

  1. Fix the hanging plate to the wall with screws.
  2. Place the keypad on the hanging plate.
  3. Tighten the anti-tamper screws at the bottom.

Pairing

Pairing with the alarm system

  1. Turn the device on with the battery switch.
  2. In the alarm system, find "Keypad" and start pairing mode.
  3. Press the doorbell button (the button with the bell) to send a signal to the alarm host.

Operation and settings

Default codes

  • Default admin code: 9876
  • User 1 code: 1234
  • Users 2 and 3: not enabled

Arming and disarming the alarm

Enter the admin or user code, or use an RFID tag. Then press the button for the mode you want.

ModeButton
Away armPress "Away" (the shield with the exit arrow)
Home armPress "Home" (the shield with the figure)
DisarmPress "Disarm" (the shield with the dash)

Doorbell function

Press the doorbell button (the button with the bell). The alarm host then sounds the doorbell.

Signals

SignalMeaning
Two short beepsError
One long beepSuccess

Pairing RFID tags

  1. Enter the admin code and press confirm (the tick).
  2. Press 1 and then confirm.
  3. Hold the RFID tags against the sensor one at a time.
  4. Press confirm twice to stop. At this step, the manual shows the icon of the cross button.

Deleting all RFID tags

  1. Enter the admin code and press confirm.
  2. Press 2 and then confirm.

All RFID tags are deleted.

Setting the admin or user code

  1. Enter the admin code and press confirm.
  2. Choose which code you want to set and then press confirm:
    • 3: set admin code
    • 4: set user 1
    • 5: set user 2
    • 6: set user 3
  3. Enter a new code of 4 to 8 digits and press confirm.
  4. Enter the code again and press confirm.

Deleting a user

  1. Enter the admin code and press confirm.
  2. Choose which user you want to delete:
    • 4: delete user 1
    • 5: delete user 2
    • 6: delete user 3
  3. Press confirm twice to delete.

Turning the microwave proximity sensor on or off

  1. Enter the admin code and press confirm.
  2. Press 7 and then confirm to turn the sensor on, or press 8 and then confirm to turn the sensor off.

The sensor wakes up the keypad automatically when someone comes within about 1 metre.

Good to know when setting up

  • During setup, press cancel (the button with the cross) to go back to the previous menu.
  • When entering a code, you can enter up to 12 digits. As long as the correct code appears somewhere in them, it is recognised.

Troubleshooting

Setup fails

If setup fails, the two codes you entered may not match. Try again.

Resetting the keypad

  1. Disconnect the power supply and turn off the battery switch.
  2. Press and hold cancel (the cross) and confirm (the tick).
  3. Turn on the battery switch.
  4. Keep holding the buttons for 10 seconds. A long beep means the reset is complete.

Good to know

  • Do not cover the light sensor on the back.
  • Turn on the battery switch before you use the keypad.
  • The keypad supports up to 10 RFID tags.

Specifications

Keypad

433 MHz versionLoRa version
Power supplyDC5V 1ADC5V 1A
Battery3.7V 1500mAh lithium battery3.7V / 1500mAh lithium battery
Working current<10mA<10mA
Standby current<100uA<100uA
Wireless433MHz, eV1527LoRa
Receiving distance / range100 metres (open space)500 metres (open space)
Temperature-10°C ~ 50°C-10°C ~ 50°C
Humidity<95% non-condensing<95% non-condensing

RFID tag

RFID protocol125KHz, 4100/4200
Maximum number of tags10