Manual Hozard HSA-1 Smoke Alarm

The Hozard HSA-1 is a photoelectric smoke alarm with 360° all-round monitoring. It runs on two 1.5V AA batteries and warns you with a buzzer of more than 85dB and a red LED. It is widely used in homes, shops, factories and warehouses for fire prevention. Read the instructions carefully before you use the smoke alarm.

What's in the box

  • Smoke alarm x1
  • Wall plug x2
  • Batteries x2
  • Rear plate x1
  • Screw x2
  • Manual x1

The product

The photoelectric fire smoke detector (smoke alarm for short) uses an infrared photoelectric sensor with a unique structural design, a reliable MCU and SMT manufacturing processes. It offers high sensitivity, high durability and low power consumption, and it is easy to use.

Button and light

  • At the top of the front is the red LED (called "red indicator" in the specifications).
  • At the bottom of the front is a single button printed with "TEST" on one side and "MUTE" on the other. In this manual it is called the test button. You use it to test the alarm and to silence the alarm temporarily.

How the smoke alarm works

The detector is designed to detect smoke from a fire at the smouldering stage or after the fire has broken out. When smoke enters the sensing chamber, it scatters the light. The change in light intensity received by the light-sensing component has a linear relationship with the smoke density. The detector continuously collects, analyses and evaluates the data. When the light intensity reaches the preset alarm threshold, the red LED starts flashing continuously and the buzzer alarm starts.

If the smoke clears from the room while the alarm is sounding, the alarm automatically returns to normal operation.

Dimensions

The smoke alarm is 90mm wide, 90mm high and 40mm deep.

Installation

The detection range is about 20m² in standard rooms up to 6m high. Install the detector on the ceiling.

Where not to install the smoke alarm

The smoke alarm is not recommended for rooms with:

  • stagnant smoke under normal conditions;
  • large dust particles, fog, vapour, fumes or corrosive air;
  • relative humidity above 95%;
  • ventilation airflow faster than 5m/s.

Installation steps

  1. Twist the rear plate anticlockwise off the detector.
  2. Using the 2 holes in the rear plate as a guide, drill 2 holes in the ceiling, 60mm apart.
  3. Screw the rear plate to the ceiling with the supplied wall plugs and screws (see Figure 1).
  4. Insert 2 x 1.5V AA batteries into the battery compartment of the detector. Observe the "+"/"-" markings.

Operation and settings

Standby

The red LED flashes about every 60 seconds. This means the alarm is in normal standby.

Smoke alarm

When the smoke alarm detects smoke particles that reach the alarm threshold, it goes into alarm mode. The buzzer makes a "beep beep" sound and the red LED flashes. When the smoke drops back below the alarm threshold, the alarm automatically returns to normal state.

Mute function

In alarm mode, press the test button to mute the alarm. The sound stops and the red indicator flashes rapidly. After a while the alarm starts again.

The mute function is a temporary measure, for example when someone is smoking or doing something else that could trigger the alarm.

Warning: only use this function when you are sure it is safe to do so.

Low battery

The red LED flashes every 55 seconds and the buzzer beeps at the same time. This means the battery is low. Replace the batteries promptly.

Test mode

Test the alarm regularly. When you press the test button, the LED flashes and an alarm sounds. When you release the button, the system returns to standby.

Troubleshooting

What you noticeCauseSolution
The detector makes a "Di" sound every 55 seconds.Low battery voltage.Replace the batteries.
Frequent false alarms.Dust contamination.Clean the internal structure with a vacuum cleaner (the black plastic part).

Good to know

Maintenance

  • If the device develops a fault, contact your supplier. Do not dismantle or repair it yourself, to avoid accidents.
  • If you are not going to use the device for a long time, remove the batteries and store the device in a dry, well-ventilated place.

Transport and storage

  • Transport the device in its original packaging and avoid heavy impacts.
  • Avoid sharp changes in temperature.
  • Maximum stacking: 6 cartons, 5 individual packages.

Specifications

ItemValue
ModelHSA-1
Rated voltageDC3V (2 × 1.5V AA batteries)
Standby current< 15uA
Alarm current< 50mA
Low voltage threshold2.5V ± 0.1V
Sound level>85dB (A) (at 3 metres, directly in front)
Smoke detection indicationnormal, alarm, low voltage, etc.
Indicatorred indicator
Mounting hole spacing60mm
Operating temperature-10 ℃~+50 ℃
Relative humidity≤ 95% RH (40 ± 2)
Output formsound and light alarm
Product weightapproximately 120g (with battery)
Dimensions90mm × 40mm (including mounting plate)
Detection rangeabout 20m² in standard rooms up to 6m high

This text comes from the official Hozard manual. The drawings are in the original manual (PDF). Updated on 1 November 2026.